{"id":779,"date":"2026-10-28T03:34:50","date_gmt":"2026-10-28T03:34:50","guid":{"rendered":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/"},"modified":"2026-10-28T03:34:50","modified_gmt":"2026-10-28T03:34:50","slug":"high-frequency-component-measurement","status":"publish","type":"post","link":"http:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/","title":{"rendered":"High Frequency Component Measurement Explained"},"content":{"rendered":"<p>A 1 nH inductor lead, a few millimeters of probe spacing, or a slightly oxidized contact can change the result more than the component under test. That is the practical challenge of <strong>high frequency component measurement<\/strong>: the measurement setup becomes part of the circuit. Engineers cannot treat a capacitor, inductor, or resistor as an isolated ideal value once test frequency rises and impedance falls.<\/p>\n<p>For production, repair, incoming inspection, and design validation, useful measurements depend on more than meter resolution. The instrument, fixture, equivalent circuit model, test frequency, calibration state, and handling method must agree with the question being asked. A meter can display many digits and still produce the wrong engineering decision if those conditions are uncontrolled.<\/p>\n<h2>High Frequency Component Measurement Starts With the Right Model<\/h2>\n<p>At low frequency, a component often appears close to its nominal value. At higher frequencies, every component carries parasitic elements. A capacitor has equivalent series resistance and equivalent series inductance. An inductor has winding resistance, interwinding capacitance, and core losses. A resistor has lead inductance and stray capacitance. The measured impedance is the combined response of all of them.<\/p>\n<p>This is why a 100 pF capacitor may not behave as 100 pF at the frequency that matters to the circuit. Near self-resonance, its capacitive reactance and parasitic inductance cancel. Beyond that point, the part can appear inductive. Similarly, an inductor approaches self-resonance as its parasitic capacitance becomes significant, after which a simple inductance reading no longer describes its behavior.<\/p>\n<p>The equivalent circuit selected by the instrument matters. Series models are generally useful when a device has low impedance, such as a low-value capacitor with measurable ESR or a high-value inductor with low winding resistance. Parallel models are often more meaningful for high-impedance devices, including small capacitors, where leakage and dielectric losses are better represented as a parallel resistance. There is no universal series-versus-parallel setting. The correct choice depends on component value, impedance, frequency, and the parameter that determines circuit performance.<\/p>\n<h2>Frequency Must Match the Engineering Question<\/h2>\n<p>A component specified for a switching converter, an RF matching network, or a high-speed interface must be evaluated at a relevant test frequency. Measuring it only at 100 Hz or 1 kHz may confirm its nominal value while missing the behavior that causes failure in service.<\/p>\n<p>That does not mean every part requires the highest available test frequency. Test at the frequency that reflects the intended operating condition or the applicable component specification. A ceramic capacitor used for decoupling may warrant measurements at several frequencies to expose capacitance change, dissipation factor, and resonance trends. A power inductor may require inductance, DCR, Q, and impedance characterization under conditions that reflect its switching environment.<\/p>\n<p>Test amplitude and DC bias are equally consequential. Some ceramic dielectrics lose substantial capacitance under DC bias. Magnetic components can change inductance as DC current shifts the core operating point. A small-signal LCR measurement establishes a controlled baseline, but it is not a substitute for evaluating components under their full operating voltage, current, and temperature. The appropriate test plan depends on whether the goal is incoming inspection, fault isolation, design verification, or qualification.<\/p>\n<h2>Parasitics Usually Dominate the Lowest Values<\/h2>\n<p>Sub-picofarad capacitance and single-digit nanohenry inductance measurements place exceptional demands on fixtures and contact geometry. A typical test lead has capacitance, inductance, resistance, and a loop area that can overwhelm the device under test. At these values, moving a probe, changing lead orientation, or placing a hand near the fixture can produce a visible shift.<\/p>\n<p>Direct-contact measurement reduces the uncontrolled length between the instrument and the component. Tweezer-form probes are particularly effective for loose chip capacitors, inductors, resistors, and diode devices because they create a short, repeatable current path and minimize handling time. A calibrated instrument such as <a href=\"https:\/\/lcr-reader.com\/colibri.html\">Smart Tweezers\u00ae<\/a> can automatically identify common component types while supporting direct measurements in ranges where ordinary clip leads are often the limiting factor.<\/p>\n<p>For board-level work, the same discipline applies. Measure as close to the target component as possible, use short connections, and recognize that neighboring components and PCB traces may remain in parallel or series with the part. In-circuit results are valuable for comparison and rapid fault finding, but they are not always equivalent to a removed-component measurement. If a reading is unexpected, isolate the component or compare it with a known-good assembly before declaring a part defective.<\/p>\n<h2>Fixture Compensation Is a Measurement Requirement<\/h2>\n<p><a href=\"https:\/\/lcr-reader.com\/clearfalsemeasurements.pdf\">Open, short, and load compensation<\/a> are not ceremonial setup steps. They characterize errors introduced by the fixture and permit the instrument to remove a substantial portion of those errors from subsequent readings.<\/p>\n<p>An open correction captures stray admittance, primarily fixture capacitance and leakage. A short correction captures residual impedance, including contact resistance and fixture inductance. A load correction, when supported and appropriate, references the system against a known standard near the expected impedance range. Compensation should be performed at the selected frequency, test level, and fixture configuration. Changing adapters, test leads, or probe spacing after compensation can invalidate its value.<\/p>\n<p>A practical discipline is to compensate at the start of a critical measurement run, after changing a fixture, and whenever results drift beyond an expected tolerance. Keep contacts clean, inspect probe tips for wear, and avoid forcing large components into fine-pitch contacts. Repeatability is often improved more by correct compensation and controlled contact pressure than by selecting a meter with another display digit.<\/p>\n<h3>Kelvin Connections and Contact Resistance<\/h3>\n<p>For low-resistance measurements, two-wire testing combines test current and voltage sensing through the same leads. Lead and contact resistance then become part of the reading. Four-wire Kelvin measurement separates the current path from the voltage-sensing path, substantially reducing this error.<\/p>\n<p>Kelvin methods are useful for low ESR capacitors, shunt resistors, battery interconnects, winding resistance, and solder-joint evaluation. They do not eliminate every high-frequency error, however. Poor geometry can still introduce inductance and coupling. Kelvin connection improves resistance accuracy; it does not replace a properly characterized high-frequency fixture.<\/p>\n<h2>Read More Than the Primary Value<\/h2>\n<p>A capacitance or inductance number alone rarely tells the full story. ESR, dissipation factor, Q, phase angle, resistance, and impedance indicate whether a device behaves as intended at the selected test condition.<\/p>\n<p>For capacitors, rising ESR or dissipation factor can identify aging electrolytics, cracked MLCCs, poor terminations, or unsuitable dielectric behavior. For inductors, Q helps reveal loss mechanisms that a nominal inductance value may hide. For resistors and interconnects, unexpected inductive behavior can expose a leaded part or layout geometry that is unsuitable for fast edges.<\/p>\n<p>Phase is particularly useful when component identification is uncertain. A nearly ideal capacitor produces a strongly capacitive phase response; an inductor produces an inductive response; a resistor trends toward zero phase. Mixed or unstable readings can indicate a lossy component, a resonant condition, contaminated contacts, or an in-circuit path that prevents a clean measurement.<\/p>\n<h2>Know When an LCR Meter Is Not Enough<\/h2>\n<p>An LCR meter provides highly effective impedance characterization across its specified frequency range, but it is not the correct instrument for every RF problem. When the question involves S-parameters, transmission-line behavior, impedance matching across a wide band, antenna performance, or resonance well into the RF and microwave range, a vector network analyzer and an appropriate calibrated fixture may be required.<\/p>\n<p>This distinction prevents a common error: extending a valid LCR result beyond the instrument&#8217;s frequency range or beyond the lumped-element behavior of the component. A handheld meter with <a href=\"https:\/\/lcr-reader.com\/documents\/MPB%20Brochure%20Spec%20Sheet.pdf\">test frequencies up to 250 kHz<\/a> can deliver fast, precise field and bench decisions for many component and power-electronics applications. It should not be represented as a replacement for broadband network analysis.<\/p>\n<p>The best measurement workflow is therefore not the one with the most equipment. It is the one that matches the instrument, fixture, compensation method, and test conditions to the failure mode or design question. When a picofarad or nanohenry can decide whether a board passes, measurement discipline is not overhead. It is the shortest path to a defensible result.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>High frequency component measurement demands control of fixtures, parasitics, models, and calibration for repeatable pF-to-nH decisions in production work.<\/p>\n","protected":false},"author":0,"featured_media":780,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-779","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>High Frequency Component Measurement Explained - Smart Tweezers LCR-Reader<\/title>\n<meta name=\"description\" content=\"High frequency component measurement demands control of fixtures, parasitics, models, and calibration for repeatable pF-to-nH decisions in production work.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"High Frequency Component Measurement Explained - Smart Tweezers LCR-Reader\" \/>\n<meta property=\"og:description\" content=\"High frequency component measurement demands control of fixtures, parasitics, models, and calibration for repeatable pF-to-nH decisions in production work.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/\" \/>\n<meta property=\"og:site_name\" content=\"Smart Tweezers LCR-Reader\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/LCRReader\" \/>\n<meta property=\"article:published_time\" content=\"2026-10-28T03:34:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/10\/high-frequency-component-measurement-explained-featured.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/\"},\"author\":{\"name\":\"\",\"@id\":\"\"},\"headline\":\"High Frequency Component Measurement Explained\",\"datePublished\":\"2026-10-28T03:34:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/\"},\"wordCount\":1315,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/high-frequency-component-measurement-explained-featured.webp\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/\",\"url\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/\",\"name\":\"High Frequency Component Measurement Explained - Smart Tweezers LCR-Reader\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/high-frequency-component-measurement-explained-featured.webp\",\"datePublished\":\"2026-10-28T03:34:50+00:00\",\"description\":\"High frequency component measurement demands control of fixtures, parasitics, models, and calibration for repeatable pF-to-nH decisions in production work.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/#primaryimage\",\"url\":\"http:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/high-frequency-component-measurement-explained-featured.webp\",\"contentUrl\":\"http:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/10\\\/high-frequency-component-measurement-explained-featured.webp\",\"width\":1536,\"height\":1024,\"caption\":\"High Frequency Component Measurement Explained\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/high-frequency-component-measurement\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"High Frequency Component Measurement Explained\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/\",\"name\":\"Smart Tweezers LCR-Reader\",\"description\":\"Smart Tweezers LCR-Reader LCR-meter\",\"publisher\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#organization\",\"name\":\"Siborg Systems Inc\",\"url\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/siborglogo-256x85-2.jpg\",\"contentUrl\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/siborglogo-256x85-2.jpg\",\"width\":256,\"height\":85,\"caption\":\"Siborg Systems Inc\"},\"image\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/LCRReader\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"High Frequency Component Measurement Explained - Smart Tweezers LCR-Reader","description":"High frequency component measurement demands control of fixtures, parasitics, models, and calibration for repeatable pF-to-nH decisions in production work.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/","og_locale":"en_US","og_type":"article","og_title":"High Frequency Component Measurement Explained - Smart Tweezers LCR-Reader","og_description":"High frequency component measurement demands control of fixtures, parasitics, models, and calibration for repeatable pF-to-nH decisions in production work.","og_url":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/","og_site_name":"Smart Tweezers LCR-Reader","article_publisher":"https:\/\/www.facebook.com\/LCRReader","article_published_time":"2026-10-28T03:34:50+00:00","og_image":[{"width":1536,"height":1024,"url":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/10\/high-frequency-component-measurement-explained-featured.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/#article","isPartOf":{"@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/"},"author":{"name":"","@id":""},"headline":"High Frequency Component Measurement Explained","datePublished":"2026-10-28T03:34:50+00:00","mainEntityOfPage":{"@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/"},"wordCount":1315,"commentCount":0,"publisher":{"@id":"https:\/\/lcr-reader.com\/blog\/#organization"},"image":{"@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/#primaryimage"},"thumbnailUrl":"http:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/10\/high-frequency-component-measurement-explained-featured.webp","inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/","url":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/","name":"High Frequency Component Measurement Explained - Smart Tweezers LCR-Reader","isPartOf":{"@id":"https:\/\/lcr-reader.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/#primaryimage"},"image":{"@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/#primaryimage"},"thumbnailUrl":"http:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/10\/high-frequency-component-measurement-explained-featured.webp","datePublished":"2026-10-28T03:34:50+00:00","description":"High frequency component measurement demands control of fixtures, parasitics, models, and calibration for repeatable pF-to-nH decisions in production work.","breadcrumb":{"@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/#primaryimage","url":"http:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/10\/high-frequency-component-measurement-explained-featured.webp","contentUrl":"http:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/10\/high-frequency-component-measurement-explained-featured.webp","width":1536,"height":1024,"caption":"High Frequency Component Measurement Explained"},{"@type":"BreadcrumbList","@id":"https:\/\/lcr-reader.com\/blog\/high-frequency-component-measurement\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lcr-reader.com\/blog\/"},{"@type":"ListItem","position":2,"name":"High Frequency Component Measurement Explained"}]},{"@type":"WebSite","@id":"https:\/\/lcr-reader.com\/blog\/#website","url":"https:\/\/lcr-reader.com\/blog\/","name":"Smart Tweezers LCR-Reader","description":"Smart Tweezers LCR-Reader LCR-meter","publisher":{"@id":"https:\/\/lcr-reader.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lcr-reader.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/lcr-reader.com\/blog\/#organization","name":"Siborg Systems Inc","url":"https:\/\/lcr-reader.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lcr-reader.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/08\/siborglogo-256x85-2.jpg","contentUrl":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/08\/siborglogo-256x85-2.jpg","width":256,"height":85,"caption":"Siborg Systems Inc"},"image":{"@id":"https:\/\/lcr-reader.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/LCRReader"]}]}},"_links":{"self":[{"href":"http:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/posts\/779","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"http:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/comments?post=779"}],"version-history":[{"count":0,"href":"http:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/posts\/779\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"http:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/media\/780"}],"wp:attachment":[{"href":"http:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/media?parent=779"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/categories?post=779"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/tags?post=779"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}