{"id":717,"date":"2026-09-09T02:20:25","date_gmt":"2026-09-09T02:20:25","guid":{"rendered":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/"},"modified":"2026-09-09T02:20:25","modified_gmt":"2026-09-09T02:20:25","slug":"how-to-measure-low-inductance","status":"publish","type":"post","link":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/","title":{"rendered":"How to Measure Low Inductance Accurately"},"content":{"rendered":"<p>A 10 nH inductor does not look like 10 nH to an instrument unless the test setup is designed to see it. A few millimeters of lead length, a test clip, or an uncorrected fixture can contribute inductance comparable to, or larger than, the device under test. That is the central challenge in how to measure low inductance: the measurement system becomes part of the result.<\/p>\n<p>For engineers evaluating small RF inductors, ferrite beads, current-sense paths, PCB structures, or sub-microhenry power components, a credible result requires more than connecting an LCR meter and reading the display. The connection method, equivalent circuit model, test frequency, compensation routine, and handling discipline all determine whether the reading is useful.<\/p>\n<h2>Define what \u201clow inductance\u201d means for the job<\/h2>\n<p>Low inductance is application-dependent. In a power design, 100 nH may be a critical value. In RF work, 100 nH is routine, while a few nanohenries can determine matching performance. From a measurement perspective, the difficult range begins when fixture and contact parasitics are no longer negligible relative to the DUT.<\/p>\n<p>The basic relationship is familiar:<\/p>\n<p>`X_L = 2\u03c0fL`<\/p>\n<p>A 10 nH inductor has a reactance of only about 0.0063 ohms at 100 kHz. At that level, contact resistance, residual fixture inductance, noise, and phase error can overwhelm the reactive signal. Raising frequency increases inductive reactance and can improve sensitivity, but it also moves the component closer to self-resonance and introduces frequency-dependent core and conductor losses. There is no universally correct test frequency.<\/p>\n<p>Start with the component\u2019s intended operating region and the manufacturer\u2019s specified test conditions. If you are qualifying incoming parts, use the datasheet frequency whenever the meter and fixture can support it. If you are characterizing a board feature or an unknown component, measure at several frequencies and record the conditions with the result.<\/p>\n<h2>Use the correct equivalent circuit<\/h2>\n<p>For most low-value inductors measured below self-resonance, select a series model. The series representation reports inductance as Ls and loss as series resistance, Rs. This usually reflects physical reality for a small wire-wound inductor, ferrite bead, trace segment, or low-impedance coil, where winding resistance and contact resistance are in series with the inductive element.<\/p>\n<p>Parallel mode can produce misleading values for low-impedance devices. It is more suitable when the DUT behaves primarily as a high-impedance parallel network. If the meter automatically selects a model, verify that the selected mode matches the device and frequency. Automatic identification is useful for rapid screening, but it does not replace engineering judgment when the value approaches the fixture\u2019s residuals.<\/p>\n<p>Also watch the quality factor, Q, or dissipation factor, D. A stable Ls reading with implausible loss data may indicate poor contact, a frequency outside the component\u2019s useful range, or a measurement that is nearing the instrument\u2019s resolution limit.<\/p>\n<h2>How to measure low inductance with the right connection<\/h2>\n<p>Two-wire leads are rarely adequate for nanohenry work. Their loop area adds inductance, and the same conductors carry test current and sense voltage. Use a four-terminal Kelvin connection whenever the instrument and fixture support it. Force terminals drive the test current; sense terminals measure the voltage directly at the DUT. This reduces the influence of lead and contact resistance.<\/p>\n<p>For AC impedance measurement, four-terminal-pair techniques provide additional control of return-current paths and terminal effects. In a handheld workflow, a short, rigid Kelvin fixture or direct-contact tweezer arrangement can provide the practical equivalent benefit: minimize separation, eliminate unnecessary lead length, and place the sensing points as close to the component body as possible.<\/p>\n<p>The geometry matters as much as the terminal count. Keep force and sense conductors short and closely coupled. Avoid long flying leads, open clip jaws, and wide current loops. Do not extend a precision fixture with ordinary jumper wire simply because the DUT is inconvenient to reach. The extension may become the dominant inductor.<\/p>\n<p>For small SMD inductors, direct contact to the end terminations is preferable to probing through long adapters. <a href=\"https:\/\/lcr-reader.com\/colibri.html\">Smart Tweezers\u00ae instruments<\/a> are particularly effective for rapid, direct-contact screening of small components, provided the contacts are clean and the measurement is performed within the instrument\u2019s specified low-inductance capability.<\/p>\n<h2>Compensate the fixture at the measurement plane<\/h2>\n<p>Compensation is not optional when the target value is comparable to fixture parasitics. The objective is to establish the reference plane at the exact location where the DUT will be connected.<\/p>\n<p>Begin with an open compensation. With the fixture arranged exactly as it will be used, but with no DUT installed, run the instrument\u2019s open correction. This characterizes residual shunt effects, primarily stray capacitance and leakage. For low inductance, the short correction is usually more consequential. Install a low-inductance short standard across the DUT connection points and run short compensation to characterize residual series impedance.<\/p>\n<p>A short standard must actually be short at the measurement frequency. A long wire link is not a valid standard for nanohenry work. Use a wide, compact conductive link or a purpose-designed calibration short that matches the fixture geometry. Re-run compensation whenever you change adapters, contact spacing, cable position, or frequency range.<\/p>\n<p>Compensation removes repeatable fixture behavior. It cannot correct unstable contact pressure, oxidation, mechanical movement, or a poor fixture design. If <a href=\"https:\/\/lcr-reader.com\/clearfalsemeasurements.pdf\">readings shift<\/a> when the component is gently touched, the setup needs improvement before more digits have any meaning.<\/p>\n<h2>Select frequency and test level deliberately<\/h2>\n<p>A higher frequency increases the reactance of a small inductor and often makes the value easier to resolve. But frequency also changes the DUT. Ferrite materials are dispersive, skin effect raises AC resistance, and parasitic capacitance can push the component toward self-resonance. Near self-resonance, an LCR meter may display a value that is mathematically computed but no longer represents a simple inductive element.<\/p>\n<p>Measure at the datasheet frequency first. Then take readings at lower and higher available frequencies. A well-behaved inductor will normally show a plausible trend in Ls, Rs, and Q. If inductance rises sharply, falls abruptly, changes sign, or becomes highly sensitive to contact position, investigate self-resonance, fixture effects, or model selection.<\/p>\n<p>Test amplitude matters for magnetic components. A ferrite-core inductor can show different inductance at different AC drive levels and DC bias conditions. Standard LCR measurement is a small-signal result. If the part will operate with substantial DC current, the small-signal reading does not establish inductance under load. Use a bias-capable characterization method or evaluate the part in its intended circuit condition.<\/p>\n<h2>Verify the result instead of trusting one reading<\/h2>\n<p>Repeatability is the first credibility check. Remove and reconnect the DUT several times. If the spread is significant relative to the tolerance being evaluated, inspect the contacts, fixture rigidity, compensation, and test frequency. Record the median or average only after the spread is understood.<\/p>\n<p>A second check is comparison with a known standard or a trusted sample. This does not need to be an identical value. A stable low-inductance reference near the range of interest confirms that the instrument, fixture, and correction workflow are behaving as expected. For production or quality systems, use <a href=\"https:\/\/lcr-reader.com\/calibration\/calibration_results.pdf\">calibrated standards<\/a> and maintain documented verification intervals.<\/p>\n<p>Finally, distinguish component inductance from circuit inductance. Measuring a part while it remains installed on a PCB commonly produces the impedance of parallel paths, attached capacitors, semiconductor junctions, and copper geometry. In-circuit readings can be useful for comparative troubleshooting, but they are not automatically the component\u2019s standalone inductance. Isolate at least one terminal when the specification requires a definitive value.<\/p>\n<h2>Build a measurement record that can be repeated<\/h2>\n<p>A low-inductance result should always travel with its conditions: instrument model, calibration status, Ls or Lp mode, test frequency, test voltage or current, fixture type, compensation state, and whether the DUT was isolated. For a 5 nH result, those details are not administrative overhead. They define what was measured.<\/p>\n<p>When the fixture is short, the reference plane is controlled, and the test conditions match the engineering question, low-inductance measurement becomes repeatable rather than optimistic. Treat every nanohenry as a system-level measurement, and the number on the display becomes a result your design, inspection, or failure analysis team can act on.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Learn how to measure low inductance with controlled fixtures, Kelvin connections, compensation, and frequency selection for repeatable nH results in lab.<\/p>\n","protected":false},"author":0,"featured_media":718,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-717","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Measure Low Inductance Accurately - Smart Tweezers LCR-Reader<\/title>\n<meta name=\"description\" content=\"Learn how to measure low inductance with controlled fixtures, Kelvin connections, compensation, and frequency selection for repeatable nH results in lab.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Measure Low Inductance Accurately - Smart Tweezers LCR-Reader\" \/>\n<meta property=\"og:description\" content=\"Learn how to measure low inductance with controlled fixtures, Kelvin connections, compensation, and frequency selection for repeatable nH results in lab.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/\" \/>\n<meta property=\"og:site_name\" content=\"Smart Tweezers LCR-Reader\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/LCRReader\" \/>\n<meta property=\"article:published_time\" content=\"2026-09-09T02:20:25+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/09\/how-to-measure-low-inductance-accurately-featured.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1536\" \/>\n\t<meta property=\"og:image:height\" content=\"1024\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"7 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/\"},\"author\":{\"name\":\"\",\"@id\":\"\"},\"headline\":\"How to Measure Low Inductance Accurately\",\"datePublished\":\"2026-09-09T02:20:25+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/\"},\"wordCount\":1335,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/how-to-measure-low-inductance-accurately-featured.webp\",\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/\",\"url\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/\",\"name\":\"How to Measure Low Inductance Accurately - Smart Tweezers LCR-Reader\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/how-to-measure-low-inductance-accurately-featured.webp\",\"datePublished\":\"2026-09-09T02:20:25+00:00\",\"description\":\"Learn how to measure low inductance with controlled fixtures, Kelvin connections, compensation, and frequency selection for repeatable nH results in lab.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/#primaryimage\",\"url\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/how-to-measure-low-inductance-accurately-featured.webp\",\"contentUrl\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/how-to-measure-low-inductance-accurately-featured.webp\",\"width\":1536,\"height\":1024,\"caption\":\"How to Measure Low Inductance Accurately\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/how-to-measure-low-inductance\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Measure Low Inductance Accurately\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#website\",\"url\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/\",\"name\":\"Smart Tweezers LCR-Reader\",\"description\":\"Smart Tweezers LCR-Reader LCR-meter\",\"publisher\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#organization\",\"name\":\"Siborg Systems Inc\",\"url\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/siborglogo-256x85-2.jpg\",\"contentUrl\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/siborglogo-256x85-2.jpg\",\"width\":256,\"height\":85,\"caption\":\"Siborg Systems Inc\"},\"image\":{\"@id\":\"https:\\\/\\\/lcr-reader.com\\\/blog\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/LCRReader\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Measure Low Inductance Accurately - Smart Tweezers LCR-Reader","description":"Learn how to measure low inductance with controlled fixtures, Kelvin connections, compensation, and frequency selection for repeatable nH results in lab.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/","og_locale":"en_US","og_type":"article","og_title":"How to Measure Low Inductance Accurately - Smart Tweezers LCR-Reader","og_description":"Learn how to measure low inductance with controlled fixtures, Kelvin connections, compensation, and frequency selection for repeatable nH results in lab.","og_url":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/","og_site_name":"Smart Tweezers LCR-Reader","article_publisher":"https:\/\/www.facebook.com\/LCRReader","article_published_time":"2026-09-09T02:20:25+00:00","og_image":[{"width":1536,"height":1024,"url":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/09\/how-to-measure-low-inductance-accurately-featured.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Est. reading time":"7 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/#article","isPartOf":{"@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/"},"author":{"name":"","@id":""},"headline":"How to Measure Low Inductance Accurately","datePublished":"2026-09-09T02:20:25+00:00","mainEntityOfPage":{"@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/"},"wordCount":1335,"commentCount":0,"publisher":{"@id":"https:\/\/lcr-reader.com\/blog\/#organization"},"image":{"@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/#primaryimage"},"thumbnailUrl":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/09\/how-to-measure-low-inductance-accurately-featured.webp","inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/","url":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/","name":"How to Measure Low Inductance Accurately - Smart Tweezers LCR-Reader","isPartOf":{"@id":"https:\/\/lcr-reader.com\/blog\/#website"},"primaryImageOfPage":{"@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/#primaryimage"},"image":{"@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/#primaryimage"},"thumbnailUrl":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/09\/how-to-measure-low-inductance-accurately-featured.webp","datePublished":"2026-09-09T02:20:25+00:00","description":"Learn how to measure low inductance with controlled fixtures, Kelvin connections, compensation, and frequency selection for repeatable nH results in lab.","breadcrumb":{"@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/#primaryimage","url":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/09\/how-to-measure-low-inductance-accurately-featured.webp","contentUrl":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/09\/how-to-measure-low-inductance-accurately-featured.webp","width":1536,"height":1024,"caption":"How to Measure Low Inductance Accurately"},{"@type":"BreadcrumbList","@id":"https:\/\/lcr-reader.com\/blog\/how-to-measure-low-inductance\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/lcr-reader.com\/blog\/"},{"@type":"ListItem","position":2,"name":"How to Measure Low Inductance Accurately"}]},{"@type":"WebSite","@id":"https:\/\/lcr-reader.com\/blog\/#website","url":"https:\/\/lcr-reader.com\/blog\/","name":"Smart Tweezers LCR-Reader","description":"Smart Tweezers LCR-Reader LCR-meter","publisher":{"@id":"https:\/\/lcr-reader.com\/blog\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/lcr-reader.com\/blog\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/lcr-reader.com\/blog\/#organization","name":"Siborg Systems Inc","url":"https:\/\/lcr-reader.com\/blog\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/lcr-reader.com\/blog\/#\/schema\/logo\/image\/","url":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/08\/siborglogo-256x85-2.jpg","contentUrl":"https:\/\/lcr-reader.com\/blog\/wp-content\/uploads\/2026\/08\/siborglogo-256x85-2.jpg","width":256,"height":85,"caption":"Siborg Systems Inc"},"image":{"@id":"https:\/\/lcr-reader.com\/blog\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/LCRReader"]}]}},"_links":{"self":[{"href":"https:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/posts\/717","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/types\/post"}],"replies":[{"embeddable":true,"href":"https:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/comments?post=717"}],"version-history":[{"count":0,"href":"https:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/posts\/717\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/media\/718"}],"wp:attachment":[{"href":"https:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/media?parent=717"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/categories?post=717"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/lcr-reader.com\/blog\/wp-json\/wp\/v2\/tags?post=717"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}